PurePower+ 3000 AC Regenerator
At PurePower, they believe that the sounds and images that come from your system should be the ones that were introduced intentionally – not those that arrived unintentionally from your utility or through your house wiring.
They believe the music shouldn’t suddenly stop or the screen flicker and dim or a recording operation fail when the utility power has a momentary sag or a short outage.
They believe that power problems such as surges, spikes, transients, and harmonic distortion shouldn’t damage and destroy expensive components catastrophically, or slowly by chronic overheating.
If you have spent time, money and effort to assemble a superior set of components that are capable of delivering a high level of audio and video performance, make sure they are given a source of clean, pure, continuous electrical power to ensure they have a chance to perform to their utmost.
Their next-generation regenerators are available in three models: PurePower+ 1500, PurePower+ 2000, and the PurePower+ 3000.
Pure Power In > Pure Sound Out
The PurePower+™ provides truly regenerated pure power regardless of what problems exist in your utility supply. This is accomplished through their double conversion technology. They convert the incoming power to produce a clean DC current, then recreate a 50 or 60 Hz reference grade AC wave form from the DC. No spikes, sags, surges or other power disturbances can be passed through from input to output.
Pure Power Continuity
In addition to pure power, the PurePower+™ provides you with something unique in audio power regenerators – protection against power outage. The PurePower+™ maintains full wattage output even when the power fails completely. All PurePower+™ models give you continued pure power at full output and quality from minutes to hours, depending on your consumption. With the option of adding PurePower+™ PowerPacks, you can have several hours of full power while your neighbors are in the dark.
Accurate voltage specs
prevent current reduction.
Some products designed to clean or filter the power can reduce the current to your amplifier. The PurePower+™ maintains a 120 volt output (230 for international models) +/- 1% with up to 92% energy efficiency and a power factor of more than .99. All of PurePower APS models can deliver their full rated wattage even during short or long duration power sags. In fact, they deliver continuous full power even if you’re getting extended periods of as low as 55 volts at the wall outlet (110 volts for international models.)
Specifications
Electrical Input | |
Nominal Voltage | 230 VAC |
Voltage Range | 100-300 VAC |
Frequency | 50 / 60 Hz Auto-sensing |
Frequency range | 40-70 Hz |
Input Connection – all models | IEC 320-C19 Input receptacle |
Input Power Factor | >0.95 @ nominal voltage |
Earth Leakage | 3.5mA, Max |
Electrical Output | |
Output Voltage | 230 VAC (208/220/230/240 VAC – User selectable) |
Voltage Regulation | ± 1% of nominal |
Output Frequency | 50 or 60 Hz – user selectable |
Frequency Regulation | ± 0.5% |
Efficiency | 88-92% depending on load |
Receptacles -PP+ 1500 | (7) Country specific receptacles or (10) Hubbell NEMA 5-15R |
Receptacles – PP+ 2000/3000 | (7) Country specific output receptacles + (2) Hubbell L6-15R or (10) Hubbell NEMA 5-15/20R + (2) Hubbell L6-15R |
Optional receptacles | Furutech High Performance Receptacle – avail for NEMA model |
Standby power consumption | 10 watts |
Output Power – PP+ 1500 | 1350 watts continuous / 1750 short term (2 min.) / 2700 (10 sec.) / 6750 (inst.) |
Output Power – PP+ 2000 | 1800 watts continuous / 2340 short term (2 min.) / 3600 (10 sec.) / 9000 (inst.) |
Output Power – PP+ 3000 | 2700 watts continuous / 3510 short term (2 min.) / 5400 (10 sec.) / 13,500 (inst.) |
Physical Characteristics | |
Form Factor | Standalone or Rack mountable |
PP+ 1500 – Single module | 13 h x 42 w x 42 w cm. 19Kg Ship wt 22Kg |
PP+ 2000 – Regen. module | 13 h x 42 w x 42 d cm, 13Kg Ship wt 16Kg |
PP+ 2000 – PowerPack Mod. | 9 h x 42 w x 42 d cm, 17Kg Ship wt 19Kg – both module 34Kg |
PP+ 3000 – Regen. module | 13 h x 42 w x 42 d cm, 13Kg Ship wt – 18Kg |
PP+ 3000 – PowerPack Mod. | 9 h x 42 w x 42 d cm, 22Kg Ship wt 24Kg – both module 42Kg |
Environmental and Safety | |
Safety Markings | CE |
EMC monitors | FCC Class B and VCCI Class II |
Surge Suppression | IEEE / ANSI C62.41 Category B (formerly 587) |
Ambient Operating Temp. | 32 – 90• F (0 – 32•C) |
Audible noise | <15 dBA |
Relative humidity | 0 to 90% non-condensing |
Additional Features | |
F-Type (coax) surge protection | 2 input, 2 output |
Phone line surge protection | 1 line input RJ11 |
RJ 45 Transient protector | Input and output jack for RJ-45 cable protection, UL497A tested |
User selectable bypass | Bypass mode may be selected at any time. Automatic bypass on sustained overload |
Diagnostics | Full system self-test on power up, user selectable diagnostics at any time |
PurePower PowerPack+™ – Minimum minutes of full load power outage protection.
Model | 0 Packs | 1 Pack | 2 Packs |
PurePower+™ 1500 | 8 | 30 | 100 |
PurePower+™ 2000/3000 | 10 | 40 | 120 |
Minutes of full power outage protection at 50% load
Model | 0 Packs | 1 Pack | 2 Packs |
PurePower+™ 1500 | 8 | 30 | 100 |
PurePower+™ 2000/3000 | 10 | 40 | 120 |